1.4.2 (Optional) Configuring Loopback on the Ethernet Interface
Context
Do as follows on the S7700 where you need to configure the loopback.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface interface-type interface-number
The interface view is displayed.
Step 3 Run:
loopback internal
The loopback is configured on the Ethernet interface.
By default, loopback is not configured on an Ethernet interface.
----End
1.4.3 (Optional) Setting the Minimum Interval for Re-enabling an
Interface
Context
Do as follows on the S7700 where you need to set the minimum interval for re-enabling an
interface.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
shutdown interval interval-value
The minimum interval for re-enabling an interface is set.
By default, the minimum interval for re-enabling an interface after the interface is disabled is
0 seconds.
----End
1.4.4 (Optional) Configuring the Interface Group
Quidway S7700 Smart Routing Switch
Configuration Guide - Ethernet 1 Ethernet Interface Configuration
Issue 01 (2011-07-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9