Context
Do as follows on the S7700 where you need to enable port isolation.
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
port-isolate mode { l2 | all }
The port isolation mode is set.
By default, ports are isolated on Layer 2 but can communicate on Layer 3.
Step 3 Run:
interface interface-type interface-number
The Ethernet interface view is displayed.
Step 4 (Optional) Run:
am isolate interface-type interface-number [ to interface-number ]
The Ethernet interface is isolated from another interface unidirectionally.
NOTE
After interface A is isolated from interface B unidirectionally, packets sent by interface A cannot reach
interface B, whereas packets sent from interface B can reach interface A.
Step 5 Run:
port-isolate enable [ group group-id ]
Port isolation is enabled.
NOTE
Ports in a port isolation group are isolated from each other, and ports in different port isolation groups can
communicate with each other. If group-id is not specified, a port is added to port isolation group 1.
----End
1.4.9 (Optional) Performing a Cable Test on an Interface
Context
A cable test detects faults on the cable connected to an interface. If the cable is working properly,
the total length of the cable is displayed. If the cable cannot work properly, the distance between
the interface and the fault point is displayed.
Procedure
Step 1 Run:
system-view
Quidway S7700 Smart Routing Switch
Configuration Guide - Ethernet 1 Ethernet Interface Configuration
Issue 01 (2011-07-15) Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
12