Step 2 Run:
garp timer leaveall timer-value
The value of the LeaveAll timer is set.
The default value of the LeaveAll timer is 1000 centiseconds (10 seconds).
Step 3 Run:
interface interface-type interface-number
The interface view is displayed.
Step 4 Run:
garp timer { hold | join | leave } timer-value
The value of the Hold timer, Join timer, or Leave timer is set.
By default, the value of the Hold timer is 10 centiseconds, the value of the Join timer is 20
centiseconds, and the value of the Leave timer is 60 centiseconds.
----End
6.3.5 Checking the Configuration
Procedure
l Run the display gvrp status command to view the status of global GVRP is enabled.
l Run the display gvrp statistics [ interface { interface-type interface-number [ to interface-
type interface-number ] }&<1-10> ] command to view the statistics about GVRP on an
interface.
l Run the display garp timer [ interface { interface-type interface-number [ to interface-
type interface-number ] }&<1-10> ] command to view the values of GARP timers.
----End
6.4 Maintaining GVRP
This section describes how to clear the statistics about GARP.
6.4.1 Clearing GARP Statistics
Context
CAUTION
GARP statistics cannot be restored after being cleared. Therefore, use this command with
caution.