EasyManua.ls Logo

IBM V7000

IBM V7000
670 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
516 IBM Flex System V7000 Storage Node Introduction and Implementation Guide
Figure 12-5 Check WWPN for WIN 2012 Host definition
4. Check adapters are all functioning with the datapath query adapter command as shown
in Example 12-2 where the output shows both adapters in a normal state and active.
Example 12-2 Datapath query adapter command
PS C:\Users\Administrator> cd "C:\Program Files\IBM\SDDDSM"
PS C:\Program Files\IBM\SDDDSM> ./datapath query adapter
Active Adapters :2
Adpt# Name State Mode Select Errors Paths Active
0 Scsi Port1 Bus0 NORMAL ACTIVE 3274 0 4 4
1 Scsi Port2 Bus0 NORMAL ACTIVE 3189 0 4 4
PS C:\Program Files\IBM\SDDDSM>
5. Enter datapath query device and press Enter to see if there are IBM Flex System V7000
Storage Node disks connected to this host. (Example 12-3).
Example 12-3 datapath query device
PS C:\Program Files\IBM\SDDDSM> ./datapath query device
Total Devices : 2
DEV#: 0 DEVICE NAME: Disk2 Part0 TYPE: 2145 POLICY: OPTIMIZED
SERIAL: 6005076000820005200000000000000A
============================================================================
Path# Adapter/Hard Disk State Mode Select Errors
0 Scsi Port1 Bus0/Disk2 Part0 OPEN NORMAL 1047 0
1 Scsi Port1 Bus0/Disk2 Part0 OPEN NORMAL 0 0
WWPNs

Table of Contents

Related product manuals