IS810N-INT Series Servo System User Manual (Brief)Chapter 5 Keypad
Function
Code
Name Unit Meaning Display Example
H0B-24
Phase current
effective value
0.01 A
It displays the effective
phase current value of
the servo motor.
4.60 A display:
H0B-26 Bus voltage 0.1 V
It displays the DC bus
voltage of the main
circuit.
540.0 V display rectied from
380 VAC:
H0B-27
Module
temperature
°C
It indicates the
temperature of the power
module inside the servo
drive.
27°C display:
H0B-33 Fault record -
It sets the historical fault
to be viewed.
0: Current fault
1: Last fault
2: Last 2nd fault
9: Last 9th fault
0: Current fault display
H0B-34
Fault code of
the selected
fault record
-
It displays the fault code
selected by H0B-33.
When there is no fault,
H0B-34 display is "E+Axis
No.000."
For example, when the axis
number is 1:
If H0B-33 = 0, H0B-34 =
E1.941, the current fault
code is 941. Display:

Table of Contents