- 144 -
IS810N-INT Series Servo System User Manual (Brief) Chapter 5 Keypad
Function
Code
Name Unit Meaning Display Example
H0B-35
Time stamp
upon
displayed fault
s
It indicates the total servo
running time when the
fault displayed in H0B-34
occurs.
When there is no fault,
H0B-35 display is "0."
If H0B-34=E2.941,
H0B-35=107374182.4
, the current fault code is 941
and the total servo running
time is 107,374,182.4s when
this fault occurs.
H0B-37
Motor
speed upon
displayed fault
RPM
It displays the servo
motor speed when the
fault displayed in H0B-34
occurs.
When there is no fault,
H0B-37 display is "0".
3000 RPM display:
-3000 RPM display:
H0B-38
Motor phase U
current upon
displayed fault
0.01 A
It displays the winding
current effective value of
the servo motor phase U
when the fault displayed
in H0B-34 occurs.
When there is no fault,
H0B-38 display is "0".
4.60 A display:
H0B-39
Motor phase V
current upon
displayed fault
0.01 A
It displays the winding
current effective value of
the servo motor phase V
when the fault displayed
in H0B-34 occurs.
When there is no fault,
H0B-39 display is "0."
4.60 A display:
H0B-40
Bus voltage
upon
displayed fault
V
It displays the DC bus
voltage of the main circuit
when the fault displayed
in H0B-34 occurs.
When there is no fault,
H0B-40 display is "0."
537.0 V display rectied from
380 VAC:

Table of Contents