IS810N-INT Series Servo System User Manual (Brief)Chapter 6 Commissioning Software
- 171 -
1. Speed JOG
Note: The
Speed JOG
function can be used only in non-EtherCAT mode (H0200CA).
Function Description: The
Speed JOG
function is mainly used to perform trial run in the
motor speed mode. Select a corresponding axis number in the
Shaft selection
drop-down
box. Set a trial run speed in
Jog speed setting
. Set
Servo state
to
On
, and the motor
enters the enabled state. At this point, hold down the left arrow button, and the motor
performs trial run in the forward direction at a set jog speed. When you release the button,
the motor stops running. Similarly, you can hold the right arrow button to make the motor
perform trial run in the reverse direction. Set
Servo
state
to
Off
, and the motor enters the
disabled state.
2. Serial Encoder Motor Parameter