EasyManua.ls Logo

Inovance IS810N-INT Series - Page 210

Inovance IS810N-INT Series
290 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IS810N-INT Series Servo System User Manual (Brief) Chapter 6 Commissioning Software
- 210 -
2.2.4. Servo Axis Parameters Settings
Unit conversion setting
Correctly set 1047586 pulses per revolution for the IS810N motor. The travel per motor
revolution does not need to be changed from its default value. The effect is similar to that
the host controller makes electronic gear ratio conversion, and the servo drive need not
make the conversion again.
Operation setting
After setting the electronic gear ratio, an alarm will be given at the maximum speed and the
parameter must be reset. Set the unit to the speed after unit conversion. 10000 pulses/s
represents 1 R/S (60 RPM) of the actual servo motor. Set the maximum speed and jogging
speed according to actual running. If there is no special requirement, other parameters
may not be set.

Table of Contents

Related product manuals