IS810N-INT Series Servo System User Manual (Brief)Appendix 1 List of Object Groups
- 279 -
Parameter group
Name
Option
Description
Setting Range Default Min. Unit Width
Change
method
Effective
Way
Hexadecimal Decimal
Group Index Parameter
2009
27h H09-38
Frequency of
low-frequency
resonance
- 10 to 1000 1000 0.1Hz 16 bits
During
running
Immediate
28h H09-39
Filter setting
of low-
frequency
resonance
- 0 to 10 2 1 16 bits At stop Immediate
200Ah/H0A Fault and Protection Parameters
200A
01h
H0A-00
Power input
phase loss
protection
0: Enable
faults and
inhibit
warnings.
1: Enable
faults and
warnings.
2: Disable
faults and
warnings.
0 to 2 0
1
16 bits
During
running
Immediate
02h H0A-01
Absolute
position limit
0: Disable
absolute
position limit
1: Enable
absolute
position limit
2: Enable
absolute
position limit
after homing
attaining
0 to 2 0 1 16 bits At stop Immediate
04h H0A-03
Retentive at
power failure
0: Do not
perform
power-down
save
1: Perform
power-down
save
2: Do not
perform
power-
down save,
shield control
power supply
undervoltage
fault
0 to 2 0 1 16 bits
During
running
Immediate
05h H0A-04
Motor
overload
protection
gain
- 50 to 300 100 1 16 bits At stop Immediate
07h H0A-06
Overload
motor level
- 0 to 400 0 1 16 bits At stop Immediate
08h H0A-07
Enable
UVW phase
sequence
auto-tuning
0: Do not
recognize
UVW phase
sequence
while
performing
angle auto-
tuning.
1: Recognize
UVW phase
sequence
while
performing
angle auto-
tuning.
0 to 1 1 1 16 bits
During
running
Immediate

Table of Contents