IS810N-INT Series Servo System User Manual (Brief) Appendix 1 List of Object Groups
- 280 -
Parameter group
Name
Option
Description
Setting Range Default Min. Unit Width
Change
method
Effective
Way
Hexadecimal Decimal
Group Index Parameter
200A
09h H0A-08
Overspeed
threshold
- 0 to 10000 0 1 RPM 16 bits
During
running
Immediate
0Dh H0A-12
Enable
runaway
protection
function
0: Disable
runaway
protection
1: Enable
runaway
protection
0 to 1 1 1 16 bits
During
running
Immediate
0Eh H0A-13
Initial angle
auto-tuning
mode
selection
0: Use Z
signal for
auto-tuning
1: Do not use
the Z signal
for jogging
auto-tuning
2: Voltage
injection auto-
tuning
3: Voltage
injection using
Z signal angle
auto-tuning
0 to 3 0 1 16 bits At stop Immediate
10h H0A-15
Motor rotation
threshold
- 1 to 1000 5 1 RPM 16 bits
During
running
Immediate
11h H0A-16
Position
deviation
threshold for
low-frequency
resonance
suppression
- 1 to 1000 5 1p 16 bits
During
running
Immediate
14h H0A-19
Time constant
of probe 1
lter
- 0 to 630 200 1 us 16 bits
During
running
Immediate
15h H0A-20
Time constant
of probe 2
lter
- 0 to 630 200 1 us 16 bits
During
running
Immediate
16h H0A-21
STO function
shield switch
0: Enable STO
function.
1: Shield STO
function.
0 to 1 0 1 16 bits At stop Immediate
17h H0A-22
Sigma_Delta
lter time
- 0 to 3 1 1 16 bits At stop
Power-on
again
18h H0A-23
TZ signal lter
time
- 0 to 31 15 years 125 ns 16 bits At stop
Power-on
again
1Ah H0A-25
Filter time
constant
of speed
feedback
display value
- 0 to 5000 50 1 ms 16 bits At stop Immediate
1Bh H0A-26
Enabling
motor
overload
shielding
0: Show motor
overload
warnings.
1: Shield
motor
overload
warnings
(E2.909)
and faults
(E2.620).
0 to 1 0 1 16 bits At stop Immediate