Fire Suppression Equipment
Type C fire extinguishers, which use noncorrosive fire retardants such as carbon dioxide
and Halotron™, are most effective for suppressing electrical fires. Type C fire extinguishers
displace oxygen from the point of combustion to eliminate the fire. For extinguishing fire
on or around equipment that draws air from the environment for cooling, you should use
this type of inert oxygen displacement extinguisher instead of an extinguisher that leaves
residues on equipment.
Do not use multipurpose Type ABC chemical fire extinguishers (dry chemical fire
extinguishers). The primary ingredient in these fire extinguishers is monoammonium
phosphate, which is very sticky and difficult to clean. In addition, in the presence of minute
amounts of moisture, monoammonium phosphate can become highly corrosive and
corrodes most metals.
Any equipment in a room in which a chemical fire extinguisher has been discharged is
subject to premature failure and unreliable operation. The equipment is considered to
be irreparably damaged.
NOTE: To keep warranties effective,do not usea dry chemicalfireextinguisher
to control a fire at or near a Juniper Networks switch or other network device
provided by Juniper. If a dry chemical fire extinguisher is used, the unit is no
longer eligible for coverage under a service agreement.
We recommend that you dispose of any irreparably damaged equipment in an
environmentally responsible manner.
Related
Documentation
General Safety Guidelines and Warnings on page 169
General Electrical Safety Guidelines and Warnings on page 197
Action to Take After an Electrical Accident on page 212
Qualified Personnel Warning
This topic applies to hardware devices in the EX Series product family, which includes
EX Series switches, the EX Series Redundant Power System (RPS), and the XRE200
External Routing Engine.
This topic also applies to hardware devices in the QFX Series and to OCX1100 switches.
WARNING: Only trained and qualified personnel should install or replace the
device.
Waarschuwing Installatie en reparaties mogen uitsluitend door getraind en
bevoegd personeel uitgevoerd worden.
Varoitus Ainoastaankoulutettu ja tevä henkilökuntasaa asentaatai vaihtaa
tämän laitteen.
173Copyright © 2015, Juniper Networks, Inc.
Chapter 15: General Safety Information

Table of Contents

Other manuals for Juniper EX2200

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX2200 and is the answer not in the manual?

Juniper EX2200 Specifications

General IconGeneral
Throughput77 Mpps
MAC address table8000 entries
Jumbo frames supportYes
Number of VLANs1024
Networking standards-
Switch typeManaged
SFP module slots quantity4
Installed SFP modules quantity0
Basic switching RJ-45 Ethernet ports quantity48
StackableNo
Product colorBlack
Power consumption (typical)100 W
Operating altitude0 - 3048 m
Non-operating altitude0 - 4877 m
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 45 °C
Storage relative humidity (H-H)0 - 95 %
Operating relative humidity (H-H)10 - 85 %
Weight and Dimensions IconWeight and Dimensions
Depth254 mm
Width441 mm
Height43 mm
Weight3600 g