CHASSISD_FASIC_HSL_LINK_ERROR
System Log Message Fchip (CB control-board-slot, ID fchip-id): link link-id failed because of error-message
Description The chassis process (chassisd) detected an error for the indicated high speed link (HSL)
for the indicated F chip on the indicated Control Board (CB).
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FASIC_INIT_ERROR
System Log Message Fchips were not configured yet
Description The chassis process (chassisd) detected that F chips were not yet initialized on the
Control Board (CB).
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
CHASSISD_FASIC_INPUT_DROP
System Log Message Fchip (CB control-board-slot, ID fchip-id): dropped drop-rate cells per second coming
from Packet Forwarding Engine pfe on FPC fpc-slot
Description The Packet Forwarding Engine divides packets into smaller units called cells for more
efficient processing. As the indicated F chip on the indicated Control Board (CB) processed
data that was received from the indicated Packet Forwarding Engine on the indicated
Flexible PIC Concentrator (FPC), it dropped the indicated number of cells per second.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FASIC_OUTPUT_DROP
System Log Message Fchip (CB control-board-slot, ID fchip-id): dropped drop-rate cells per second destined
for Packet Forwarding Engine pfe on FPC fpc-slot
Description The Packet Forwarding Engine divides packets into smaller units called cells for more
efficient processing. As the indicated F chip on the indicated Control Board (CB) processed
data before sending it to the indicated Packet Forwarding Engine on the indicated Flexible
143Copyright © 2010, Juniper Networks, Inc.
Chapter 18: CHASSISD System Log Messages

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper JUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010 and is the answer not in the manual?

Juniper JUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010 Specifications

General IconGeneral
BrandJuniper
ModelJUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010
CategorySoftware
LanguageEnglish

Related product manuals