CHASSISD_FCHIP_CONFIG_MD_ERROR
System Log Message Fchip fchip-id: invalid number of Md chips (count) for Packet Forwarding Engine pfe on
FPC fpc-slot
Description The chassis process (chassisd) detected an invalid number of Md chips for the indicated
F chip, Packet Forwarding Engine and Flexible PIC Concentrator (FPC).
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
CHASSISD_FCHIP_CONFIG_RATE_ERROR
System Log Message Fchip fchip-id: unable to set rate limit on port port
Description The chassis process (chassisd) could not set the rate limit for the indicated F chip and
port.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
CHASSISD_FCHIP_CONFIG_READ_ERROR
System Log Message Fchip fchip-id: unable to read configuration register
Description The chassis process (chassisd) could not read a configuration register on the indicated
F chip.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
CHASSISD_FCHIP_FTOKEN_ERROR
System Log Message Fchip fchip-id: Ftoken overflow/underflow set (data) at address
Description The chassis process (chassisd) detected an underflow or overflow error on the indicated
F chip.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.