CHASSISD_FM_ERROR_F13_FB_TXP
System Log Message F13SIBsib-slot_FB_fiber-bundle LCC lcc ST_SIB_Lto-lcc-sib is error-message
Description In a Tx-Plus routing matrix, the fiber-optic cable between each Switch Interface Board
in a T1600 routing node (called a ST-SIB-L) must connect to a specific SIB port on the
TX-Plus Matrix platform (called a F13SIB). The cable connected at the indicated F13SIB
had the indicated error.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FM_ERROR_F13_FB_TX_VC
System Log Message error-message on F13SIBfrom-sfc-sib_FBfiber-bundle VCSEL vcsel Channel vcsel-channel
connected to LCC lcc SIB_L to-lcc-sib
Description In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they
travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called
ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs).
The chassis process (chassisd) on the routing node that houses the indicated F13SIB
detected the indicated error as packets that were traveling in the indicated direction were
translated between electrical and optical media.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FM_ERROR_F13_VC_PWR
System Log Message FM: High power difference at F13SIBfrom-sfc-sib_FBfiber-bundle VCSEL vcsel Channel
vcsel-channel connected to LCC lcc SIB_Lsib-slot
Description In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they
travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called
ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs).
The chassis process (chassisd) on the SFC routing node that houses the indicated F13SIB
detected higher than configured receive power difference levels on the indicated
fiber-bundles connected to the indicated LCC ST-SIB-L.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Copyright © 2010, Juniper Networks, Inc.156
Junos 10.3 System Log Messages Reference