Action Contact your technical support representative.
CHASSISD_FM_ERROR_SIB_L_FB_HSR
System Log Message FM: HSR error occurred on link from SIB-S port F(s-row,s-port) to SIB-L#sib-slot port
F(l-row,l-port)
Description In a routing matrix, packets traverse both electrical and optical media as they travel
between the Switch Interface Boards (SIBs) in the T640 routing nodes (called SIB-Ls)
and the SIBs in the TX Matrix platform (called SIB-Ss). The chassis process (chassisd)
on the routing node that houses the indicated SIB-L detected an error in the electrical
path between the indicated ports on the SIB-L and the corresponding SIB-S.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FM_ERROR_SIB_L_FB_RX_VC
System Log Message error-message on LCC lcc SIB_Lfrom-lcc-sib_FBfiber-bundle VCSEL vcsel Channel
vcsel-channel connected to F13SIBto-sfc-sib
Description In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they
travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called
ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs).
The chassis process (chassisd) on the routing node that houses the indicated ST-SIB-L
detected the indicated error as packets that were traveling in the optical media.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FM_ERROR_SIB_L_FB_SMF
System Log Message FM: error-message error occurred on link to-from-sib SIB-L#sib-slot to-from-scc SCC
Description In a routing matrix, packets traverse both electrical and optical media as they travel
between the Switch Interface Boards (SIBs) in the TX Matrix platform (the switch-card
chassis, or SCC) and the SIBs in the T640 routing nodes (called SIB-Ls). The chassis
process (chassisd) on the routing node that houses the indicated SIB-L detected the
indicated error as packets that were traveling in the indicated direction were translated
between electrical and optical media.
Type Error: An error occurred
Severity error
157Copyright © 2010, Juniper Networks, Inc.