Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FM_ERROR_SIB_L_FB_TXP
System Log Message LCC lcc ST-SIB-L:sib-slot Fiber-bundle:fiber-bundle is error-message
Description In a Tx-Plus routing matrix, the fiber-optic cable between each Switch Interface Board
in a T1600 routing node (called a ST-SIB-L) must connect to a specific SIB port on the
TX-Plus Matrix platform (called a F13SIB). The cable connected at the indicated ST-SIB-L
had the indicated error.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FM_ERROR_SIB_L_FB_TX_VC
System Log Message error-message on LCC lcc SIB_Lfrom-lcc-sib_FBfiber-bundle VCSEL vcsel Channel
vcsel-channel connected to F13SIBto-sfc-sib
Description In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they
travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called
ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs).
The chassis process (chassisd) on the routing node that houses the indicated ST-SIB-L
detected the indicated error as packets that were traveling in the indicated direction were
translated between electrical and optical media.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FM_ERROR_SIB_L_HSR_PFE
System Log Message FM: error-message on LCC:lcc FPCfpc-slot_pfe link to ST-SIB-Lto-lcc-sib_fchip-id
Description In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they
travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called
ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs).
The chassis process (chassisd) on the routing node that houses the indicated ST-SIB-L
detected an error in the electrical path between the indicated ST-SIB-L and the indicated
PFE on the FPC.
Type Error: An error occurred
Copyright © 2010, Juniper Networks, Inc.158
Junos 10.3 System Log Messages Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper JUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010 and is the answer not in the manual?

Juniper JUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010 Specifications

General IconGeneral
BrandJuniper
ModelJUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010
CategorySoftware
LanguageEnglish

Related product manuals