Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FM_ERROR_SIB_L_HSR_TXP
System Log Message FM: error-message on LCC:lcc FPCfpc-slot_pfe link connected by
ST-SIB-Lfrom-lcc-sib_fchip-id_s-port_FBfiber-bundle to F13SIBto-sfc-sib
Description In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they
travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called
ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs).
The chassis process (chassisd) on the routing node that houses the indicated ST-SIB-L
detected an error in the electrical path between the indicated ports on the SIB-L and the
corresponding F13SIB.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FM_ERROR_SIB_L_MISMATCH
System Log Message FM: fiber cable from SIB-L#sib-slot possibly connected to wrong SIB-S
Description In a routing matrix, the fiber-optic cable between each Switch Interface Board in a T640
routing node (called a SIB-L) must connect to a specific SIB port on the TX Matrix platform
(called a SIB-S). The cable originating at the indicated SIB-L was possibly plugged into
the wrong SIB-S port or wrong SIB-S.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_FM_ERROR_SIB_L_VC_PWR
System Log Message FM: High power difference at LCC lcc SIB_Lsib-slot_FBfiber-bundle VCSEL vcsel Channel
vcsel-channel connected to F13SIBfrom-sfc-sib
Description In a Tx-Plus routing matrix, packets traverse both electrical and optical media as they
travel between the Switch Interface Boards (SIBs) in the T1600 routing nodes (called
ST-SIB-Ls) and the SIBs in the TX Matrix Plus platform (called F13SIBs and F2S-SIBs).
The chassis process (chassisd) on the routing node that houses the indicated ST-SIB-L
detected higher than configured receive power levels on the indicated fiber-bundles
connected to the indicated LCC ST-SIB-L.