Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_MIC_OFFLINE_NOTICE
System Log Message Taking MIC mic-slot in FPC fpc-slot offline: reason
Description The chassis process (chassisd) took the indicated MIC offline, for the indicated reason.
Type Event: This message reports an event, not an error
Severity notice
Facility LOG_DAEMON
CHASSISD_MULTILINK_BUNDLES_ERROR
System Log Message Unable to set multilink Frame Relay UNI NNI bundles for PIC pic-slot in FPC fpc-slot
Description The chassis process (chassisd) could not create multilink Frame Relay user-to-network
interface and network-to-network interface (MLFR UNI NNI [FRF.16]) bundles for the
indicated PIC.
Type Error: An error occurred
Severity warning
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_NO_PCGS
System Log Message No PCG status
Description The chassis process (chassisd) could not find an operational Packet Forwarding Engine
Clock Generator (PCG). Packet forwarding is halted until a PCG becomes operational.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_NO_SCGS
System Log Message No SCG state
Description The chassis process (chassisd) could not find an operational SONET Clock Generator
(SCG). To continue functioning correctly, SONET/SDH interfaces that use an SCG as
their clock source must find another source.
Type Error: An error occurred
187Copyright © 2010, Juniper Networks, Inc.
Chapter 18: CHASSISD System Log Messages