Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_OFFLINE_NOTICE
System Log Message Routing Engine offline: message
Description The chassis process (chassisd) took the Routing Engine offline.
Type Event: This message reports an event, not an error
Severity critical
Facility LOG_DAEMON
CHASSISD_OID_GEN_FAILED
System Log Message Unable to generate OID: oid (error-message)
Description The chassis process (chassisd) could not generate an object identifier (OID) for the
indicated object.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Contact your technical support representative.
CHASSISD_OVER_TEMP_CONDITION
System Log Message Chassis temperature over temperature degrees C (message); routing platform will
shutdown in duration seconds if condition persists
Description The temperature of one or more components (field-replaceable units, or FRUs) exceeded
the indicated temperature, which is the upper of two thresholds. The fans (and impellers,
if applicable) were in the indicated state. If the temperature does not go below the
threshold within four minutes after the chassis process (chassisd) detects this condition,
the chassisd process shuts down the routing platform. When this message was logged,
the indicated number of seconds remained before shutdown.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Increase cooling in the area around the chassis.
Copyright © 2010, Juniper Networks, Inc.188
Junos 10.3 System Log Messages Reference