CHASSISD_OVER_TEMP_SHUTDOWN_TIME
System Log Message Chassis temperature above temperature degrees C description (> duration seconds);
powering down all FRUs
Description The chassis process (chassisd) shut down the routing platform because the temperature
of one or more components exceeded the indicated threshold temperature for the
indicated amount of time. Continued operation at the excessive temperature could
damage the routing platform.
Type Error: An error occurred
Severity critical
Facility LOG_DAEMON
Action Increase cooling in the area around the chassis.
CHASSISD_PARSE_COMPLETE
System Log Message Using new configuration
Description The chassis process (chassisd) successfully parsed its configuration file.
Type Event: This message reports an event, not an error
Severity info
Facility LOG_DAEMON
CHASSISD_PCI_ERROR
System Log Message function-name: error-message
Description While performing an operation on the PCI bus, the chassis process (chassisd) encountered
the indicated error.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Cause A software or a hardware problem occurred.
Action Contact your technical support representative.
CHASSISD_PEER_UNCONNECTED
System Log Message function-name: peer not connected
Description The chassis process (chassisd) processed a packet for a peer with an invalid or missing
connection.
Type Event: This message reports an event, not an error
189Copyright © 2010, Juniper Networks, Inc.
Chapter 18: CHASSISD System Log Messages