Severity error
Facility LOG_DAEMON
Cause In most cases, this error is caused by peers transitioning up and down unexpectedly. The
error is usually transient and nonfatal.
CHASSISD_PEM_BREAKER_TRIP
System Log Message Circuit breaker tripped for power supply pem-slot
Description The circuit breaker was tripped for the indicated power entry module (PEM).
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
Action Turn on the affected PEM manually.
CHASSISD_PEM_IMPROPER
System Log Message Power supply pem-slot improper for platform
Description Old PEM is not supported in this platform.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Replace old PEM with proper newer PEM
CHASSISD_PEM_INPUT_BAD
System Log Message error-message for power supply pem-slot (status bits: 0xstatus-code); check circuit
breaker
Description The chassis process (chassisd) detected the indicated error condition for the indicated
power entry module (PEM).
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
Action Check the status of the circuit breaker and the input connections.
CHASSISD_PEM_NOT_SUFFICIENT
System Log Message Unable to power up FPC fpc-slot, because no three-input 240-A power supply is installed
Copyright © 2010, Juniper Networks, Inc.190
Junos 10.3 System Log Messages Reference