Description On the T1600 router, the T1600-FPC4 ES Flexible PIC Concentrator (FPC) requires that
at least one three-input 240-A power supply be installed. The chassis process (chassisd)
did not power on the T1600-FPC4 ES in the indicated slot because the required power
supply is not installed.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
Action Install at least one three-input 240-A power supply.
CHASSISD_PEM_OVERLOAD
System Log Message Overload condition for power supply pem-slot (status bits: 0xstatus-code);
Description The indicated power entry module (PEM) reported an output voltage overload condition.
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
Cause There might have been excessive load on the PEM.
CHASSISD_PEM_TEMPERATURE
System Log Message Temperature check bit set for power supply pem-slot; airflow might be inadequate
Description The chassis process (chassisd) detected that the 'temperature check bit' was set in the
status bit mask for the indicated power entry module (PEM).
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
Cause The PEM might have exceeded its temperature threshold, possibly because the airflow
through it was inadequate.
CHASSISD_PEM_VOLTAGE
System Log Message Power supply pem-slot reports problem; check output voltage
Description The indicated power entry module (PEM) reported a problem with its output voltage.
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
Cause There might have been excessive load on the PEM.
191Copyright © 2010, Juniper Networks, Inc.
Chapter 18: CHASSISD System Log Messages