Type Error: An error occurred
Severity error
Facility LOG_DAEMON
RPD_RIP_JOIN_MULTICAST
System Log Message Unable to join multicast group on interface-name: error-message
Description RIP cannot run on the indicated interface, because the routing protocol process (rpd)
could not join the RIP multicast group as required for RIP version 2 multicast updates.
Type Error: An error occurred
Severity error
Facility LOG_DAEMON
RPD_RSVP_BACKUP_DOWN
System Log Message Backup for protecting LSP lsp-name down, using bypass bypass-lsp-namereason
Description When link protection is enabled, a backup label-switched path (LSP) is needed to
maintain a protected LSP's control-plane connectivity when topology failures are
detected. The backup LSP for the indicated protected LSP failed. The failure can cause
traffic loss because the protected LSP tears down when there is no backup. If the reason
for the backup failure can be determined, it is reported in the message.
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
RPD_RSVP_BYPASS_DOWN
System Log Message RSVP bypass bypass-lsp-name for protecting interface interface-name went downreason
Description The indicated RSVP link-protection bypass, which was protecting the indicated interface,
was terminated. If the reason for the termination can be determined, it is reported in the
message.
Type Event: This message reports an event, not an error
Severity warning
Facility LOG_DAEMON
RPD_RSVP_BYPASS_UP
System Log Message RSVP bypass bypass-lsp-name for protecting interface interface-name came up
Description The indicated RSVP link-protection bypass was established to protect the indicated
interface.
Type Event: This message reports an event, not an error
555Copyright © 2010, Juniper Networks, Inc.
Chapter 73: RPD System Log Messages