UI_SCHEMA_CHECKOUT_FAILED
System Log Message Schema is out of date and needs to be rebuilt
Description The JUNOS user interface schema file records all CLI commands and configuration
statements available in the JUNOS software. While initializing, the new management
process (mgd) determined that the schema's sequence number means that the schema
is incompatible with the JUNOS software installed on the routing platform.
Type Error: An error occurred
Severity alert
Facility ANY
Cause The schema is out of date.
Action None; mgd will rebuild the schema based on the current JUNOS version.
UI_SCHEMA_MISMATCH_MAJOR
System Log Message Schema major version mismatch for package package-name (expected-value vs.
received-value)
Description The JUNOS user interface schema file records all CLI commands and configuration
statements available in the JUNOS software. While initializing, the management process
(mgd) discovered that the major part (for example, '5' in '5.x') of the schema version
number does not match the major version number of the JUNOS software installed on
the routing platform. The mismatch could lead to corruption of the configuration database.
Type Error: An error occurred
Severity error
Facility ANY
Cause The schema is incompatible with the installed JUNOS software.
Action None; mgd will rebuild the schema based on the current JUNOS version.
Cause An internal software failure occurred.
Action Contact your technical support representative.
UI_SCHEMA_MISMATCH_SEQUENCE
System Log Message Schema header sequence numbers mismatch for package package-name
Description The JUNOS user interface schema file records all CLI commands and configuration
statements available in the JUNOS software. Schema sequence numbers serve as a
checksum of the configuration data schema and ensure that the software used to access
Copyright © 2010, Juniper Networks, Inc.654
Junos 10.3 System Log Messages Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper JUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010 and is the answer not in the manual?

Juniper JUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010 Specifications

General IconGeneral
BrandJuniper
ModelJUNOS OS 10.3 - SYSTEM LOG MESSAGES REFERENCE 7-12-2010
CategorySoftware
LanguageEnglish

Related product manuals