Safety module objects
© 2022 KEB Automation KG
523
Index
Name
affects on KEB specific object:
Type 3
Type 5
0x66B8
SLI support
Number of supported instances of
SLI. (8 pieces)
0x66BA
S_UL_SLI_32 Bit
The upper position limit. This value is
the adjusted position window / 2nd
unit revolutions.
0x66BC
S_LL_SLI_32 Bit
The lower position limit. This value is
the adjusted position window / 2nd
unit revolutions.
0x66BD
Error Reaction SLI
Either STO or SS1.
0x66D0
SDIp support
The safety module supports SDI pos-
itive.
0x66D1
SDIn support
The safety module supports SDI neg-
ative.
0x66D3
S_Zero_SDI_32Bit
The drive must not leave the adjusted
position window at motor standstill.
Unit revolutions.
0x66E0
SSM support
Number of supported instances of
SSM (Safe speed monitoring). (8
pieces)
066E2
N_UL_SSM_32Bit
The upper speed limit for SSM. The
scaling is 19 bit integer positions and
13 bit decimal places.
0x66E4
N_LL_SSM32Bit
The lower speed limit for SSM. The
scaling is 19 bit integer positions and
13 bit decimal places.
0xE600
FSoE Slave frame ele-
ments
The elements of the FSoE frames
which are sent to the safe master.
(raw data)
0xE601
FSoE SafeInputs
The elements of the FSoE frames
which are sent to the safe master.
0xE700
FSoE Master frame ele-
ments
The elements of the FSoE frames
which are sent by the safe master.
0xE701
FSoE SafeOutputs
The elements of the FSoE frames
which are sent by the safe master.