Chapter 3 - page 7
Operator’s manual ASTRONAUT
M-HE.002.1003
Time during which the valve remains in an open position to fill the cleaning
tank after having reached the maximum level. This prevents the valve from
being closed off by a wave before the tank has been filled with enough water.
After having reached the tank empty level, water is allowed into the tank
during the time period adjusted here. The objective is to condense the vapour
and to drain the remainders of the cleaning agent.
Adjustment of cleaning agent concentration Astri
®
-lin, a lye-based cleaning
agent
1
. A quantity between approx. 0,5 and 1,0% is required.
The quantity supplied by the peristaltic pump is determined in the test menu.
Also refer to section 3.4.16 ’Testmenu’ > Cleaning. Allow the pump to run for
a few seconds and collect the liquid in a measuring jug. To obtain the correct
concentration of 1,0%, a quantity of 0,3 - 0,45 l (0.4 - 0.5 q.t.) of cleaning
agent is required in case of a full cleaning tank 30 - 45 l (32 - 48 q.t.).
Adjustment of the cleaning agent concentration Astri
®
-L brush cleaning
agent
1
in the water for cleaning of the cleaning rollers.
Adjustment of the cleaning agent concentration Astri
®
-L brush cleaning
agent
1
in the rinsing water for post rinsing.
1) Before use carefully read the manufacturers instructions.
Afterfill time tank
1 sec
After rinsetime tank
5 sec
Addition detergent
(Astri-lin)
30 sec
Addition detergent
(Astri-cid)
15 sec
Addition detergent
(Astri-L)
cleaning rolls
7 sec
Addition detergent
(Astri-L)
Rinsing
8 sec