• Read “Installation Guidelines” on page 51 and “Safety inspection checklist” on page 52 to ensure that you
work safely.
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 68.
• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding systems.
CAUTION:
When removing a new LACM from the shipping box, lift out the cold plate assembly with the shipping
tray attached to prevent thermal grease on the cold plate assembly from damage.
Prepare the following screwdrivers to ensure you can install and remove the corresponding screws properly.
Torque screwdriver type list Screw Type
Torx T30 head screwdriver Torx T30 screw
Procedure
Step 1. Prepare your server.
a. Install the liquid detection sensor module holder to the chassis.
1. Align the liquid detection sensor module holder to the corresponding screw hole on the
chassis.
2.
Tighten the screw and ensure that the holder is secured in place.
b. Install the radiator tray to the chassis.
144