Step 1. Remove the top cover. See “Remove the top cover” on page 243.
Step 2. If there is a RAID flash power module installed on the back side of the air baffle, disconnect the
RAID flash power module cable first.
Step 3. Grasp the air baffle and carefully lift it out of the server.
Figure 30. Air baffle removal
Attention: Operating the server with the air baffle removed might damage server components. For
proper cooling and airflow, install the air baffle before you power on the server.
After you finish
If you are instructed to return the component or optional device, follow all packaging instructions, and use
any packaging materials for shipping that are supplied to you.
Install the air baffle
Follow instructions in this section to install the air baffle.
About this task
Depending on the model, your server might not have an air baffle installed. The air baffle you want to install
might be different from following illustrations, but the installation method is the same.
S033
CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with
metal, which might result in spattered metal, burns, or both.