Figure 102. M.2 cage installation
Push the M.2 cage into the chassis until the release latch clicks into place.
Step 5. Reconnect the cables to the M.2 backplane. See
“M.2 drive backplane” on page 267.
Step 6. Install the top cover. See
“Install the top cover” on page 244.
After you finish
1. Complete the parts replacement. See
“Complete the parts replacement” on page 246.
2. Use the Lenovo XClarity Provisioning Manager to configure the RAID. For more information, see:
https://sysmgt.lenovofiles.com/help/topic/lxpm_frontend/lxpm_product_page.html.
Demo video
Watch the procedure on YouTube
OCP module replacement
Use this information to remove and install the OCP module.
Notes:
The OCP module is available only on some models.
If ThinkSystem Redundant System Management Port Adapter is installed on the server, it will not be
displayed on the PCIe card list of system management software, such as XCC, LXPM, and so on.
Remove the OCP module
Use this information to remove the OCP module.
About this task