Figure 251. Cable routing for six front SAS/SATA drives and four front AnyBay drives bays with an 8i or 16i SFF RAID
adapter (Gen 3)
Table 46. Mapping between one front AnyBay backplane and an SFF HBA/RAID adapter
Backplane From To
Front BP (SAS)
1 SAS 0, SAS 1 1 C0, C1
Front BP (NVMe)
2 NVMe 0–1
2 PCIe 2
3 NVMe 2–3
3 PCIe 1
Front BP (SAS)
4 SAS 2 4 C2
6 x 2.5'' SAS/SATA + 2 x 2.5'' AnyBay + 2 x 2.5'' NVMe (liquid cooling)
See this section to understand the cable routing of six front SAS/SATA drives, two AnyBay drives and two
front NVMe drives for the liquid cooling configuration.
Chapter 6. Internal cable routing 283