Step 1. Touch the static-protective package that contains the backplane to any unpainted surface on the
outside of the server. And then, take the backplane out of the package and place it on a static-
protective surface.
Step 2. Align the two pins on the backplane with the corresponding holes in the chassis.
Figure 33. Installation of backplane for ten 2.5-inch hot-swap drives
Step 3. Lower the backplane into the chassis. Ensure that the pins pass through the holes and the
backplane is fully seated in place.
Step 4. Connect the cables to the system board assembly and the backplane. See
Chapter 6 “Internal
cable routing” on page 249
. If the cable connectors come with protective dust caps, make sure to
remove them before plugging in.
After you finish
1. Reinstall all the drives and drive fillers into the drive bays. See
“Install a 2.5/3.5-inch hot-swap drive” on
page 117
.
2. Complete the parts replacement. See
“Complete the parts replacement” on page 246.
Demo video
Watch the procedure on YouTube
Remove the front 3.5-inch drive backplane
Use this information to remove the front 3.5-inch drive backplane.
About this task
Attention:
• Read
“Installation Guidelines” on page 51 and “Safety inspection checklist” on page 52 to ensure that you
work safely.
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 68.
82
ThinkSystem SR630 V3 User Guide