Remove a power-supply-unit air baffle
Use this information to understand how to remove a power-supply-unit air baffle.
About this task
S033
CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with
metal, which might result in spattered metal, burns, or both.
Attention: Read
“Installation Guidelines” on page 51 and “Safety inspection checklist” on page 52 to ensure
that you work safely.
Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 68.
Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with an
electrostatic-discharge wrist strap or other grounding systems.
Watch the procedure
A video of this procedure is available on YouTube:
https://www.youtube.com/playlist?list=PLYV5R7hVcs-
CfNsWy-689CRZHExrZEi9I
.
Procedure
Step 1. Remove the top cover. See
“Remove the top cover” on page 243.
Step 2. Disconnect the cables adjacent to the power-supply-unit air baffle. For proper operation guidelines,
see
Chapter 6 “Internal cable routing” on page 249.
Step 3. Remove the power-supply-unit air baffle.
Chapter 5. Hardware replacement procedures 173