CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with
metal, which might result in spattered metal, burns, or both.
S014
CAUTION:
Hazardous voltage, current, and energy levels might be present. Only a qualified service technician is
authorized to remove the covers where the label is attached.
Attention:
Read
“Installation Guidelines” on page 51 and “Safety inspection checklist” on page 52 to ensure that you
work safely.
Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 68.
Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding systems.
Operating the server with the top cover removed might damage server components. For proper cooling and
airflow, install the top cover before you turn on the server.
Note: A new top cover comes without a service label attached. If you need a service label, order it together
with the new top cover and attach the service label to the new top cover first.
Procedure
Step 1. Check your server and ensure that:
All cables, adapters, and other components are installed and seated correctly and that you have
not left loose tools or parts inside the server.
All internal cables are connected and routed correctly. See
Chapter 6 “Internal cable routing” on
page 249
.
Chapter 5. Hardware replacement procedures 245

Table of Contents

Other manuals for Lenovo ThinkSystem SR630 V3

Related product manuals