Figure 328. Cable routing for 6 front SAS/SATA drives and 4 front AnyBay drives bays and a 16i SFF RAID adapter (Gen 3)
with 2 x 2.5 rear SAS/SATA drives installed
Table 135. Mapping between one front AnyBay and one rear SAS/SATA backplanes and an SFF HBA/RAID adapter
Backplane From To
Front BP (SAS)
1 SAS 0, SAS 1 1 C0, C1
Front BP (NVMe)
2 NVMe 2–3, 0–1
2 PCIe 1, 2
Front BP (SAS)
3 SAS 2 3 C2
Front and Rear BP (SAS)
4 SAS (rear) 4 C3
Cable routing with a CFF RAID adapter
The following tables show the mapping relationship between backplane connectors and a 16i CFF RAID
adapter (Gen 3 or Gen 4).
Chapter 6. Internal cable routing 389