EasyManua.ls Logo

Lenovo ThinkSystem SR630 V3 - Page 436

Lenovo ThinkSystem SR630 V3
508 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 361. Cable routing for 10 AnyBay drives with a 16i SFF RAID adapter (Gen 3)
Table 168. Mapping between one front AnyBay backplane and an SFF HBA/RAID adapter
Backplane From To
Front BP (SAS)
1 SAS 0–3, 4–7 1 C0, C1
Front BP (NVMe)
2 NVMe 0–1
2 PCIe 5
Front BP (power)
3 Power and sideband
3 Power port for front BP
Front BP (SAS) 4 SAS 8–9 4 C2
Front BP (NVMe)
5 NVMe 2–3
5 PCIe 6
6 NVMe 4–5
6 PCIe 3
7 NVMe 6–7
7 PCIe 2
8 NVMe 8–9
8 PCIe 1
10 x 2.5'' NVMe (Gen 5)
See this section to understand the cable routing of 10 front NVMe drives with 10 x 2.5'' backplane (Gen 5)
installed.
To connect cables for a 7mm drive backplane, refer to
“7mm drive backplane” on page 270.
To connect cables for M.2 drives, refer to
“M.2 drive backplane” on page 267.
426 ThinkSystem SR630 V3 User Guide