Table 35. Recommended installation priority for different types of PCIe adapters (continued)
Installation priority
5. Re-timer adapter 11. External storage controller
6. GPU adapter 12. COM port bracket
When installing a specific PCIe adapter, refer to the following suggested slot installation priority:
Table 36. Recommended slot installation priority for PCIe adapters
Recommended slot
installation priority
PCIe adapters
Slot 1
SFF HBA/RAID adapter
ThinkSystem x16 Gen 4.0 Re-timer adapter (for 4 x NVMe)
ThinkSystem x16 Gen 5.0 Re-timer adapter
Note: The RAID/HBA 4350/5350/9350-8i adapters are supported only in the server
configuration with 4 x 3.5-inch SAS/SATA front bays or 8 x 2.5-inch SAS/SATA front drive
bays.
Slot 2 (configured as a
full-height slot)
ThinkSystem Broadcom 57504 10/25GbE SFP28 4-Port PCIe Ethernet Adapter
ThinkSystem Intel E810-DA4 10/25GbE SFP28 4-Port PCIe Ethernet Adapter
Note: Both Broadcom 57504 PCIe Ethernet adapter and Intel E810-DA4 PCIe Ethernet
adapter can be installed to slot 2 or slot 3.
Slot 1 > Slot 3 > Slot 2
ThinkSystem Mellanox ConnectX-6 HDR100 IB/100GbE VPI 1-port x16 PCIe 3.0 HCA
ThinkSystem Mellanox ConnectX-6 HDR100 IB/100GbE VPI 2-port x16 PCIe 3.0 HCA
ThinkSystem Mellanox ConnectX-6 Dx 100GbE QSFP56 2-port PCIe Ethernet Adapter
ThinkSystem NVIDIA ConnectX-7 NDR400 OSFP 1-port PCIe Gen5 Adapter
ThinkSystem NVIDIA ConnectX-7 NDR200/HDR QSFP112 2-port PCIe Gen5 x16
InfiniBand Adapter
ThinkSystem NVIDIA A2 16GB PCIe Gen4 Passive GPU
ThinkSystem NVIDIA A2 16GB PCIe Gen4 Passive GPU w/o CEC
Slot 2 > Slot 3 A COM port upgrade kit needs to be installed in slot 2 or 3 as a normal PCIe adapter. In this
case, a riser and a bracket are needed.
Slot 1 > Slot 2 > Slot 3 Other PCIe adapters not mentioned above.
Notes:
For Mellanox ConnectX-6 HDR IB/200GbE Single Port x16 PCIe Adapter, refer to the
following slot priority depending on the quantity of adapters to be installed:
Two adapters: slot 1, slot 3 or slot 2, slot 3
Three adapters: slot 1, slot 2, slot 3
The RAID/HBA 4350/5350/9350-8i/16i adapters and the Intel E810-DA2 OCP adapter or
the Intel E810-DA2 PCIe adapter cannot be installed in the same system.
Note: The RAID 940-8i or RAID 940-16i adapter supports Tri-mode. When Tri-mode is enabled, the server
supports SAS, SATA and U.3 NVMe drives at the same time. NVMe drives are connected via a PCIe x1 link to
the controller.
Chapter 5. Hardware replacement procedures 63