About this task
Attention:
Read
“Installation Guidelines” on page 51 and “Safety inspection checklist” on page 52 to ensure that you
work safely.
Power off the server and peripheral devices and disconnect the power cords and all external cables. See
“Power off the server” on page 68.
Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding systems.
Procedure
Step 1. Touch the static-protective package that contains the backplane to any unpainted surface on the
outside of the server. And then, take the backplane out of the package and place it on a static-
protective surface.
Step 2. Connect the cables to the backplane. See
Chapter 6 “Internal cable routing” on page 249.
Step 3. Put the backplane down into place.
Figure 37. Installation of backplane for 16 EDSFF drives
a. Align the hole on the backplane with the pin on the chassis, place it down, and slightly slide
it as shown.
b.
Tighten the screw to secure the backplane.
Step 4. Connect the cables to the system board assembly and the backplane. See
Chapter 6 “Internal
cable routing” on page 249
. If the cable connectors come with protective dust caps, make sure to
remove them before plugging in.
After you finish
1. Reinstall all the drives and drive cages into the drive bays. See
“Install a hot-swap EDSFF drive” on page
121
.
2. Complete the parts replacement. See
“Complete the parts replacement” on page 246.