8400 StateLine C | Reference manual
Motor control (MCTRL)
V/f characteristic control (VFCplus)
Tip!
Cases of application for this function:
Operation of reluctance motors or synchronous motors during controlled
acceleration (reduction of natural frequencies caused by wrong excitation).
Adaptation of the voltage requirement for the motor, depending on specific
load conditions.
Proceed as follows to open the dialog for parameterising the motor control:
1. »Engineer« Go to the Project view and select the 8400 StateLine controller.
2. Go to Workspace and change to the Application parameters tab.
3. Select the motor control "10: VFCplus: V/f definable" from the Overview dialog box
in the Motor control list field:
4. Click the Motor control V/f definable button to change to the Overview Motor
control V/f dialog box.
This dialog level only shows a simplified signal flow with the most important
parameters.
When you click the >>More details button in the left-most position, a signal
flow with more details/parameters is displayed.