8400 StateLine C | Reference manual
Function library
Function blocks | L_RLQ_1
846 L Firmware 11.00 - DMS 8.0 EN - 10/2011
16.1.41 L_RLQ_1
This FB links a selected direction of rotation to the quick stop function with wire-break
protection.
Inputs
Outputs
Function
[16-23] Truth table of the FB L_RLQ, 0 = FALSE, 1 = TRUE
Identifier
Data type
Information/possible settings
bCw
BOOL
Input
•TRUE = CW rotation
bCCw
BOOL
Input
TRUE = CCW rotation
Identifier
Data type
Value/meaning
bQSP
BOOL
Output signal for quick stop (QSP)
bCwCcw
BOOL
Output signal for CW/CCW rotation
TRUE = CCW rotation
Inputs Outputs Notes
bCw bCCw bCwCcw bQSP
TRUE TRUE FALSE TRUE The inputs have this status only if a TRUE signal is being applied to
both
inputs at the moment of switch-on!
See also FB illustration above, "Init" = 1.
If one of the inputs has the TRUE status, the following truth table applies:
FALSE FALSE FALSE TRUE See also FB illustration above, "Init" = 0.
TRUE FALSE FALSE FALSE
FALSE TRUE TRUE FALSE
TRUE TRUE