8400 StateLine C | Reference manual
Technology applications
TA "Actuating drive speed"
306 L Firmware 11.00 - DMS 8.0 EN - 10/2011
7.2.3.4 Terminal 16
Connection Assignment Connection Assignment
X101/NC-NO LA_NCtrl.bDriveFail
X4/RFR LA_NCtrl.bFailReset X3/A1U LA_NCtrl.nMainSetValue_a *
X4/DI1 LA_NCtrl.bJogSpeed1 X3/A1I -
X4/DI2 LA_NCtrl.bJogSpeed2 X3/O1U LA_NCtrl.nMotorSpeedAct_a *
X4/DI3 LA_NCtrl. bRLQCw * 10 V 100 % reference speed (C00011
)
X4/DI4 LA_NCtrl. bRLQCcw X4/DO1 LA_NCtrl.bDriveReady
+
=
X4
DI3
DI2
DI4
GIO
24I
DI1
RFR
24E
+
X3
AR
A1U
GA
A1I
DO1
O1U
COM
NC
NO
X101
CG
CL
CH
X1
Controller enable / reset error
External
supply
24 V DC
Fixed setpoint 1/3
Fixed setpoint 2/3
Cw rotation quick stop
Ccw rotation quick stop
DriveReady
Speed setpoint
Actual speed value
DriveFail
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com