7.2.3.4 Terminal 16
Connection Assignment Connection Assignment
X101/NC-NO LA_NCtrl.bDriveFail
X4/RFR LA_NCtrl.bFailReset X3/A1U LA_NCtrl.nMainSetValue_a *
X4/DI1 LA_NCtrl.bJogSpeed1 X3/A1I -
X4/DI2 LA_NCtrl.bJogSpeed2 X3/O1U LA_NCtrl.nMotorSpeedAct_a *
X4/DI3 LA_NCtrl. bRLQCw * 10 V ≡ 100 % reference speed (C00011
)
X4/DI4 LA_NCtrl. bRLQCcw X4/DO1 LA_NCtrl.bDriveReady