Firmware ≤ 11.00 - DMS 8.0 EN - 10/2011 L 275
8400 StateLine C | Reference manual
I/O terminals
Analog terminals
6.2.1 Parameterising analog input
Click the button on the Terminal assignment tab to go to the parameterisation dialog
for the analog input:
Short overview of the parameters for the analog input:
Parameter Info Lenze setting
Value Unit
Analog input 1
C00034/1
AIN1: Config. 0: -10V..+10V
C00026/1
AIN1: Offset 0.00 %
C00027/1
AIN1: Gain 1.0000
C00028/1 AIN1: Input voltage - V
C00029/1 AIN1: Input current - mA
C00033/1 AIN1: Output value (to application) - %
C00440/1
PT1 rounding AnalogIn1 10 ms
C00598/1
Resp. to open circuit AIN1 3: TroubleQuickStop
Highlighted in grey = display parameter