EasyManua.ls Logo

Lenze 8400 StateLine C - L_Digitallogic_1

Lenze 8400 StateLine C
891 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 11.00 - DMS 8.0 EN - 10/2011 L 797
8400 StateLine C | Reference manual
Function library
Function blocks | L_DigitalLogic_1
16.1.16 L_DigitalLogic_1
This FB provides a binary output signal created by a logic operation of the input signals.
Optionally, one of the constant binary values independent from the input signals can be
output.
Output of a constant binary value
Logical ANDing of the inputs
Logical ORing of the inputs
Output depending on the combination of the input signals
Inputs
Outputs
Identifier
Data type
Information/possible settings
bIn1
BOOL
Input signal 1
bIn2
BOOL
Input signal 2
bIn3
BOOL
Input signal 3
Identifier
Data type
Value/meaning
bOut
BOOL
Output signal
/B'LJLWDO/RJLFB
E,Q
!



E2XW
&
&
&
&
E,Q
E,Q
&
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com