Firmware 11.00 - DMS 8.0 EN - 10/2011 L 93
8400 StateLine C | Reference manual
Device control (DCTRL)
Device state machine and device statuses
4.2.7 OperationEnabled
The drive controller is in this device status if the controller inhibit is deactivated and no
error ("Trouble" or "TroubleQSP") has occurred.
If the operation is enabled and the magnetisation in case of sensorless vector control
(SLVC) has been completed, the motor follows the setpoint determined by the active
application.
Depending on certain conditions, a status change takes place based on the
"OperationEnabled" device status.
Related topics:
wCANControl/wMCIControl control words
( 103)
4.2.8 Warning
This display may occur in all device statuses if a monitoring mode responds, the error
response "Warning" or "Warning locked" has been parameterised for.
If the error is no longer active, the previous device status is displayed.
LED DRIVE READY LED DRIVE ERROR Display in C00137 Display in status word 1 (C00150)
Bit 11 Bit 10 Bit 9 Bit 8
OFFOperationEnabled0101
Change condition Changeover to the device status
Control bit "EnableOperation" of a control channel = "0"
OR terminal RFR = LOW level (controller inhibit).
SwitchedOn
Control bit "SwitchOn" of a control channel = "0". ReadyToSwitchOn
Undervoltage in the DC bus. Trouble/Fault (depending on C00600/1)
Error with error response "Trouble" occurs. Trouble
Error with error response "TroubleQSP" occurs. TroubleQSP
LED DRIVE READY LED DRIVE ERROR Display in C00137 Display in status word 1 (C00150)
Bit 11 Bit 10 Bit 9 Bit 8
Warning 0110