8400 StateLine C | Reference manual
Commissioning
Commissioning of the "Actuating drive speed" technology application
56 L Firmware 11.00 - DMS 8.0 EN - 10/2011
3.6.3 Parameterising the motor control
1. Go to Workspace and change to the Application parameters tab.
The motor control parameters, among other things, can be found on the left:
2. In the Motor control list field (C00006
), select the desired motor control.
3. Adapt the motor control parameters:
Related topics:
Notes on motor control
( 49)
Motor control (MCTRL)
( 106)
Parameter Lenze setting Info
Value Unit
V/f base frequency
(C00015
)
50.0 Hz Adapting the V/f base frequency
( 132)
Imax in motor mode
(C00022
)
47.00 A Optimising the Imax controller
( 136)
Vmin boost
(C00016
)
1.60 % Adapting the Vmin boost
( 134)