Firmware 11.00 - DMS 8.0 EN - 10/2011 L 55
8400 StateLine C | Reference manual
Commissioning
Commissioning of the "Actuating drive speed" technology application
3.6.2 Creating an »Engineer« project and going online
The following steps serve to describe a general method for creating a project with the
Select component from catalogue option. For this purpose, individual components
(controller, motor, etc.) are selected from selection lists.
1. Start the »Engineer«.
2. Create a new project with the Start-up wizard and the Select component from
catalogue option:
–In the Component step, select the 8400 StateLine controller.
–In the Device modules step, select the available communication module.
–In the Application step, select the "Actuating drive speed" application. (The
application can also be selected any time afterwards via the Application parameter
tab or C00005
.)
–In the Other components step, select other components (motor / gearbox) to be
added to the project.
3. Go online.
After a connection to the controller has been established, the following status is
displayed in the Status line:
4. Transfer parameter set to the device.
This command serves to overwrite the current parameter settings in the controller
with the parameter settings of the »Engineer« project.
You can find detailed information on the general use of the »Engineer« in the
online help which you can call with [F1].
The chapter "Working with projects" describes, among other things, all
options of the Start-up wizard which are available to create a new »Engineer«
project.