EasyManua.ls Logo

Lenze 8400 StateLine C

Lenze 8400 StateLine C
891 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 11.00 - DMS 8.0 EN - 10/2011 L 787
8400 StateLine C | Reference manual
Function library
Function blocks | L_Compare_1
16.1.11.1 Function 1: nIn1 = nIn2
This function compares two signals with regard to equality. It can, for instance, provide the
comparison "actual speed equals setpoint speed " (n
act
= n
set
).
Use C00682
to set the window within which the equality is to apply.
Use C00681
to set a hysteresis if the input signals are not stable and the output
oscillates.
[16-4] Function 1: Switching performance
[16-5] Function 1: Example
n C00681: Hysteresis
o C00682
: Window
TRUE
FALSE
bOut
nIn2_a
nIn1_a

n C00681: Hysteresis
o C00682
: Window
nIn1_a
nIn2_a
TRUE
FALSE
bOut
t
t