8400 StateLine C | Reference manual
Function library
System blocks | LS_ParFree_a
866 L Firmware 11.00 - DMS 8.0 EN - 10/2011
16.2.16 LS_ParFree_a
This system block outputs 4 parameterisable analog signals.
Outputs
Parameter
Identifier
Data type
Value/meaning
nPar1_a ... nPar4_a
INT
From version 11.00.00:
nC472_1_a ... nC472_4_a
Output of the analog signals parameterised in C00472/1...4
Note: From version 11.00.00 the outputs are named according to the respective
setting parameter for an easier allocation.
Parameter Possible settings Info
C00472/1...4
-199.99 % +199.99 Selection of analog signals to be
output
Q3DUBD
Q3DUBD
Q3DUBD
Q3DUBD
&
&
&
&
/6B3DU)UHHBD