EasyManua.ls Logo

Lenze 8400 StateLine C

Lenze 8400 StateLine C
891 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 11.00 - DMS 8.0 EN - 10/2011 L 865
8400 StateLine C | Reference manual
Function library
System blocks | LS_ParFree
16.2.15 LS_ParFree
This system block outputs 4 parameterisable 16-bit signals.
Outputs
Parameter
Identifier
Data type
Value/meaning
wPar1 ... wPar4
WORD
From version 11.00.00:
wC471_1 ... wC471_4
Output of the 16-bit signals parameterised in C00471/1...4
Note: From version 11.00.00 the outputs are named according to the respective
setting parameter for an easier allocation.
Parameter Possible settings Info
C00471/1...4
0x0000 0xFFFF Setting of the 16-bit signals to be
output
Z3DU
Z3DU
Z3DU
Z3DU
&
&
&
&
/6B3DU)UHH
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com

Table of Contents

Other manuals for Lenze 8400 StateLine C

Related product manuals