8400 StateLine C | Reference manual
Function library
Function blocks | L_NSet_1
820 L Firmware 11.00 - DMS 8.0 EN - 10/2011
16.1.29.1 Main setpoint path
The signals in the main setpoint path are limited to a value range of ±32767.
The signal at nNSet_a is first led via the JOG selection function.
A selected JOG value switches the nNSet_a input inactive. Then, the subsequent signal
conditioning operates with the JOG value.
C00221 0.000 s 999.900 Deceleration time T
if
for the
additional setpoint
Lenze setting: 0.000 s
C00241
0.00 % 100.00 Hysteresis window for zero detection
of speed output setpoint (output
bRfgIEqO)
Lenze setting: 0.50 %
C00632/1...3
0.00 % 199.99 Maximum limit values for the speed
blocking zones
Selection of the maximum limit
values for the blocking zones in
which the speed must not be
constant.
Lenze setting: 0.00 %
C00633/1...3
0.00 % 199.99 Minimum limit values for the speed
blocking zones
Selection of the minimum limit
values for the blocking zones in
which the speed must not be
constant.
Lenze setting: 0.00 %
C00634
Status (bit-coded)
Bits that are not listed are
reserved for future extensions.
Bit 0 No blocking zone active
Bit 1 Blocking zone 1 active
Bit 2 Blocking zone 2 active
Bit 3 Blocking zone 3 active
Bit 4 Jog in blocking zone
Bit 5 MaxLimit active
Bit 6 MinLimit active
C00635
-199.99 % 199.99 nMaxLimit
Maximum speed setpoint for
speed setpoint limitation
Lenze setting: 199.99 %
C00636
-199.99 % 199.99 nMinLimit
Minimum speed setpoint for
speed setpoint limitation
Lenze setting: -199.99 %
Parameter Possible settings Info