Firmware 11.00 - DMS 8.0 EN - 10/2011 L 341
8400 StateLine C | Reference manual
Technology applications
TA "Switch-off positioning"
7.3.5 Setting parameters (short overview)
Parameter Info Lenze setting
Value Unit
C00011 Appl.: Reference speed 1500 rpm
C00012
Accel. time - main setpoint 2.000 s
C00013
Decel. time - main setpoint 2.000 s
C00105
Decel. time - quick stop 2.000 s
C00039/1
Fixed setpoint 1 40.00 %
C00039/2
Fixed setpoint 2 60.00 %
C00039/3
Fixed setpoint 3 80.00 %
C00039/4...15
Fixed setpoint 4 ... 15 0.00 %
C00101/1...15
Add. accel. time 1 ... 15 0.000 s
C00103/1...15
Add. decel. time 1 ... 15 0.000 s
C00105
Decel. time - quick stop 2.000 s
C00106
Auto-DCB: Hold time 0.500 s
C00107
DCB braking: Hold time 999.000 s
C00134
L_NSet_1: Ramp smoothing 0: Off
C00182
L_NSet_1: S-ramp time PT1 20.00 s
C00190
L_NSet_1: Setpoint arithmetic 0: Out = Set
C00220
L_NSet_1: Acceleration time - add. setpoint 0.000 s
C00221
L_NSet_1: Deceleration time - add. setpoint 0.000 s
C00241
L_NSet_1: Hyst. NSet reached 0.50 %
C00488/1
InputSens.SlowDown1 0: Level
C00488/2
InputSens.Stop1 0: Level
C00488/3
InputSens.SlowDown2 0: Level
C00488/4
InputSens.Stop2 0: Level
C00488/5
InputSens.SlowDown3 0: Level
C00488/6
InputSens.Stop3 0: Level
C00632/1
L_NSet_1: Blocking speed 1 max 0.00 %
C00632/2
L_NSet_1: Blocking speed 2 max 0.00 %
C00632/3
L_NSet_1: Blocking speed 3 max 0.00 %
C00633/1
L_NSet_1: Blocking speed 1 min 0.00 %
C00633/2
L_NSet_1: Blocking speed 2 min 0.00 %
C00633/3
L_NSet_1: Blocking speed 3 min 0.00 %
C00635
L_NSet_1: nMaxLimit 199.99 %
C00636
L_NSet_1: nMinLimit -199.99 %
C00670
L_OffsetGainP_1: Gain 1.0000
C00671
L_OffsetGainP_2: Gain 1.0000
C00672
L_OffsetGainP_3: Gain 1.0000
C00696
L_OffsetGainP_1: Offset 0.00 %
C00697
L_OffsetGainP_2: Offset 0.00 %
C00698
L_OffsetGainP_3: Offset 0.00 %
C00800
L_MPot_1: Upper limit 100.00 %
C00801
L_MPot_1: Lower limit -100.00 %
C00802
L_MPot_1: Acceleration time 10.0 s
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com